Attenuation

SCPI Command :

[SOURce<HW>]:AREGenerator:SWUNit:CABLecorr:CONNector<DI>:TX<ST0>:USER:ATTenuation
class AttenuationCls[source]

Attenuation commands group definition. 1 total commands, 0 Subgroups, 1 group commands

get(connector=Connector.Default, txIndexNull=TxIndexNull.Default) float[source]
# SCPI: [SOURce<HW>]:AREGenerator:SWUNit:CABLecorr:CONNector<DI>:TX<ST0>:USER:ATTenuation
value: float = driver.source.areGenerator.swunit.cableCorr.connector.tx.user.attenuation.get(connector = repcap.Connector.Default, txIndexNull = repcap.TxIndexNull.Default)

Requires [:SOURce<hw>]:AREGenerator:SWUNit:CABLecorr:CONNector<di>:RX|TX:MODE USER or [:SOURce<hw>]:AREGenerator:SWUNit:CABLecorr:CONNector<di>:RX|TX:MODE S2P. Sets a user-defined attenuation value.

param connector:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Connector’)

param txIndexNull:

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Tx’)

return:

areg_cable_corr_at: float Range: -50 to 50

set(areg_cable_corr_at: float, connector=Connector.Default, txIndexNull=TxIndexNull.Default) None[source]
# SCPI: [SOURce<HW>]:AREGenerator:SWUNit:CABLecorr:CONNector<DI>:TX<ST0>:USER:ATTenuation
driver.source.areGenerator.swunit.cableCorr.connector.tx.user.attenuation.set(areg_cable_corr_at = 1.0, connector = repcap.Connector.Default, txIndexNull = repcap.TxIndexNull.Default)

Requires [:SOURce<hw>]:AREGenerator:SWUNit:CABLecorr:CONNector<di>:RX|TX:MODE USER or [:SOURce<hw>]:AREGenerator:SWUNit:CABLecorr:CONNector<di>:RX|TX:MODE S2P. Sets a user-defined attenuation value.

param areg_cable_corr_at:

float Range: -50 to 50

param connector:

optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Connector’)

param txIndexNull:

optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Tx’)